Kratos Microwave Israel

Full Line Product Catalog

Series 91 and 92 Miniature Broadband SPST Switches

Application Notes for RF Switches

SERIES 91 and 92

Series 91 and 92 switches provide high performance characteristics over a multi-octave range. Series 91 models cover the frequency range of 1 to 18 GHz, while Series 92 models cover the range from 0.2 to 4.0 GHz. These miniature switches measure only 0.75 x 0.69 x 0.38 inches.

Both series use an integrated circuit assembly of up to four PIN diodes mounted in a microstrip transmission line. The circuit configuration is shown below.

RF Schematic Diagram Series 91 and 92 SPST Switches 

Application of a positive current to the bias terminal switches the unit OFF since the diodes are biased to a low resistance value. With zero or negative voltage at the bias terminal, the diodes are biased to high resistances and the unit is switched ON. Maximum rise and fall times are less than 10 nsec.

SERIES F91 AND F92

The Series F91 and F92 switches are the same as the corresponding Series 91 and 92 models except the units are equipped with integrated drivers, and the dimensions of the units are 0.75 x 0.75 x 0.38 inches. The proper current required to switch the unit ON or OFF is provided by the integral driver which requires +5 and -12 to -15 volt power supplies and is controlled by an external logic signal.

  • Frequency range (Series 91): 1 to 18 GHz
  • Frequency range (Series 92): 0.2 to 4 GHz
  • Low VSWR and Insertion loss
  • Up to 80 dB isolation
  • Less than 10 nsec rise and fall time
  • Miniature size, light weight

UNITS With INTEGRATED DRIVERS

Miniature Broadband SPST Switch with Integrated Driver Model F9114A
F9114A
Miniature Broadband SPST Switch with Integrated Driver Model F9214A
F9214A

DRIVERLESS UNITS

Miniature Broadband SPST Switch Model 9114
9114
Miniature Broadband SPST Switch Model 9112
9112

PERFORMANCE CHARACTERISTICS

  FREQUENCY (GHz)
 MODEL NO.(1)  CHARACTERISTIC 0.2 to 0.5 0.5 to 1.0 1.0 to 2.0 2.0 to 4.0 4.0 to 8.0 8.0 to 12.4 12.4 to 18.0
9112*, F9112A*

Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)

--
--
--
--
--
--
36
0.8
1.3
40
0.8
1.3
45
0.9
1.6
45
1.1
1.75
45
1.8
1.75
9114, F9114A

Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)

--
--
--
--
--
--
60
0.9
1.4
74
0.9
1.4
80
1.0
1.75
80
1.6
1.75
80
2.5
2.0
9214*, F9214A

Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)

40
1.0
1.5
45
1.0
1.5
50
1.0
1.5
50
1.0
1.5
--
--
--
--
--
--
--
--
--

*Special-order product. Consult factory before ordering. 

9112, F9112A,
9114, F9114A
Switching Speed(2)
   Rise Time ............................................ 10 nsec max.
   Fall Time ............................................. 10 nsec max.
   ON Time(4) ........................................... 20 nsec max.
   OFF Time(4) ......................................... 20 nsec max.
   Repetition Rate(4)................................. 20 MHz max.
   
9214, F9214A
Switching Speed(2)
   Rise Time ............................................ 10 nsec max. 
   Fall Time ............................................. 10 nsec max. 
   ON Time(4)............................................ 40 nsec max. 
   OFF Time(4)..........................................
40 nsec max. 
   Repetition Rate(4).................................
10 MHz max. 

Power Supply Requirements
Driverless Units 
   For rated isolation.............................. +35 mA  
   For rated Insertion loss...................... -10V 






Units With Integrated Drivers
................. +5V ±5%, 65 mA

                                                                  -12 to -15V, 20 mA 

 

Power Handling Capability 

Without Performance Degradation

  
   
   Without integrated drivers.................

   With integrated drivers ......................



1W cw or peak(3)


1W cw or peak

Survival Power....................................... 2W average, 75W peak (1 µsec max. pulse width)
Control Characteristics 
Control Input Impedance......................
TTL, two-unit load. (A unit load is 1.6 mA sink current and 40 µA source current)
Control Logic .......................................



Logic "0" (-0.3 to +0.8V) for switch ON

Logic "1" (+2.0to +5.0V) for switch OFF

NOTES
(
1) Models prefixed with 'F" are equipped with integrated TTL-compatible drivers; models without the 'F" prefix are current-controlled units and are furnished without drivers.
(2) For driverless units, shaped current pulses must be provided by the user.
(3) 2W cw or peak with -20V back bias.
(4) ON and OFF time and repetition rate specifications are only applicable to Series F91 and F92 units.

ENVIRONMENTAL RATINGS
 Operating Temperature Range
   Series 91 and 92.............................
   Series F91 and F92 ........................



-54°C to +110°C


-55°C to +110°C

Non-Operating Temperature Range.. -65°C to +125°C
Humidity ............................................ MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%)
Shock ................................................. MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec)
Vibration............................................. MIL-STD-202F, Method 204D, Cond. B (.06" double
amplitude or 15G, whichever is less)
Altitude................................................ MIL-STD-202F, Method 105C, Cond. B (50,000 ft.)
Temp. Cycling...................................... MIL-STD-202F, Method 107D, Cond. A, 5 cycles
AVAILABLE OPTIONS
Option No.

Description

3 SMA female bias/control connector 
7 Two SMA male RF connectors
9 Inverse control logic; logic "0" for
switch OFF, logic "1" for switch ON
(Not applicable to Series 91/92) 
10 One SMA male (J1) and one SMA female (J2)
RF connectors
33 EMI filter solder-type bias/control terminal 
41(1) Internal video filter, port J1 only 
42(1) Internal video filter, port J2 only 
43(1) Internal video filter, both ports 
 55(2)   Frequency operation 0.5 to 18 GHz
64A SMB male bias/control connector
G09 Meeting the specified Environmental Ratings
G12 RoHS Compliant
G18  REACH Compliant

NOTES
(1) Not applicable to models 9214 & F9214.
See Video Filter Options on Switches Applications Notes.
(2) Applicable only to 1 to 18 GHz switches. See impact of Option 55 on specifications


DIMENSIONS AND WEIGHTS

Dimensions and Weights Series 91 and 92 SwitchesDimensions and Weights Series 91 and 92 Switches
Dimensions in  mm (Inches) Tolerances, unless otherwise indicated: .XX ±.02; .XXX ±.005  
 
 


The information contained in this data sheet is basic marketing information and does not contain any export controlled information.