Power Supply Requirement |
|
+5V ±5%, 90 mA |
|
–12V ±5%, 75 mA |
|
|
|
Control Characteristics |
|
Control Input Impedance ........... |
TTL, advanced Schottky, one-unit load. (A unit load is 0.6 mA sink current and 20µA source current.) |
Control Logic ........................... |
Logic "0" (-0.3 to +0.8V) for switch ON and logic "1" (+2.0 to +5.0V) for switch OFF |
OPTION (G09) ENVIRONMENTAL RATINGS
|
Operating Temperature Range...........
|
-54°C to + 110°C |
Non-Operating Temperature Range...... |
-65°C to + 125°C |
Humidity .......................... |
MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%) |
Shock .............................. |
MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration ......................... |
MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less) |
Altitude ............................ |
MIL-STD-202F, Method 105C, Cond. B (50,000 ft.) |
Temp. Cycling ................. |
MIL-STD-202F, Method 107D, Cond. A, 5 cycles |