Power Handling Capability |
Without Performance Degradation |
Units without "T" or "W" suffix: 1W cw or peak |
Units with "T" or "W" suffix: |
Input to any "OFF" port: 100 mW cw or peak |
Input to any "ON" port: 1W cw or peak |
Input to common port: 1W cw or peak |
Survival Power |
Units without "T" or "W" suffix: 1W average, 75W peak (1μsec max. pulse width) |
Units with "T" or "W" suffix: |
Input to any "OFF" port: 1W average, 10W peak (1μsec max. pulse width) |
Input to any "ON" port: 1W average, 75W peak (1μsec max. pulse width) |
Input to common port:1W average, 75W peak (1μsec max. pulse width) |
|
Switching Time(2) |
SERIES 91/F91/G91 |
ON time.............................................. 250 nsec max. |
OFF time............................................. 250 nsec max. |
With Option C37................................. 100 nsec max. |
SERIES 92/F92/G92 |
ON time.............................................. 500 nsec max. |
OFF time............................................. 500 nsec max. |
NOTE
(2) For driverless units, shaped current pulses must be provided by the user |
|
|
Power Supply Requirements |
SERIES 91/92/F91/F92 |
Driverless Units |
Bias current required at each port for rated isolation and Insertion loss. |
Port OFF.............................................+50 mA |
Port ON.............................................. -50 mA |
Units With Integrated Drivers |
(For one port ON) .............................. +5V ±5%, 250 mA
-12 to -15V, 80 mA |
SERIES G91/G92 |
(For one port ON) ................................... +5V ±5%, 150 mA
+15V ±5%, 60 mA |
Control Characteristics |
SERIES 91/92/F91/F92 |
Units With Integrated Drivers |
Control Input Impedance.................. TTL, low power Schottky, one unit load. (A unit load is 0.8 mA sink current and 40 μA source current.) |
Control Logic...................................... Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF. |
SERIES G91/G92 |
Control Input Impedance.................. Schottky TTL, one unit load. (A unit load is 2.0 mA sink current and 50 μA source current.) |
Control Logic..................................... Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF.
|
|
|
ENVIRONMENTAL RATINGS - Option G09
|
Temperature Range
|
|
Operating........................ -54°C to +110°C
|
Non-Operating................ -65°C to +125°C
|
Humidity............................... MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%)
|
Shock.................................... MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration............................... MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less)
|
Altitude................................. MIL-STD-202F, Method 105C, Cond. B (50,000 ft.)
|
Temp. Cycling........................ MIL-STD-202F, Method 107D, Cond. A, 5 cycles
|
|
|
AVAILABLE OPTIONS |
|
Option No. Description |
|
3 SMA female bias/control connectors |
7 SMA male RF connectors
|
9 Inverse control logic; logic "0" for port OFF and logic "1" for port ON (Not applicable to Series 91/92)
|
33 EMI filter solder-type bias/control terminals |
41(3) Internal video filter, common port only |
42(3) Internal video filter, output ports only
|
43(3) Internal video filter, all ports |
55 Frequency range 0.5 to 18 GHz. See impact of this Option on the specifications. |
64A SMB male bias/control connectors
|
C37(4) 100 nsec. switching time |
G09 Guaranteed to meet Environmental Ratings |
G12 RoHS Compliant |
G18 REACH Compliant |
|
NOTES
|
(3) Not applicable to Series 92/F92/G92. See Video Filter Options on Switches
|
(4) Not applicable to series 92/F92/C92. Minimum order buy of 100 switches |