CHARACTERISTIC
FREQUENCY (GHz)
Min Isolation (dB)
60
74
80
Max Insertion Loss (dB)
0.9
1.2
1.6
2.5
VSWR (ON STATE)
1.4
1.75
2.0
Switching Characteristics
Rise Time.....................
10 nsec. max
Fall Time......................
ON Time.......................
25 nsec. max
OFF Time.....................
20 nsec. max
Power Handling Capability
Without Performance Degradation....
200 mw cw or peak
Survival Power...............
2W average, 75W peak (1 µsec max pulse width)
Control Characteristics
Control Input Impedance.............
TTL, one-unit load.
Control Logic
Logic "0"...................
(max. VIL = 0.8V) for switch ON
Logic "1"...................
(min. VIH = 2V) for switch OFF
ENVIRONMENTAL RATING - OPTION G09
1.
Operating Temperature Range – -54°C to +95°C.
2.
3.
Shock – MIL-STD-202G, Method 213B, Condition A (50G, 11 msec).
4.
Vibration – MIL-STD-202G, Method 204D, Condition B (0.06” double amplitude or 15G,
5.
Altitude – MIL-STD-202G, Method 105C, Condition B (50,000 ft.).
6.
Temperature Cycling – MIL-STD-202F, Method 107D, Condition A (5 cycles.).
AVAILABLE OPTIONS (Consult factory before ordering)
Option No.
7
9
11
49
High Reliability Screening per the following Table 1
62
G09
DIMENSIONS AND WEIGHT
Model E9114H
Wt.: 0.28oz. (8 gm) approx.
Dimensions in mm (Inches) Tolerances, unless otherwise indicated: .XX ±.02; .XXX ±.005