Control Characteristics |
Control Input Impedance.......... |
TTL, low power Schottky, one unit load. (A unit load is 0.8 mA sink current and 40 µA source current.) |
Control Logic........................... |
Logic “0” (–0.3 to +0.8V) for port ON and logic “1” (+2.0 to +5.0 V) for port OFF. |
|
|
AVAILABLE OPTIONS
|
1. Operating Frequency Range |
2. Mechanical Configuration |
|
ENVIRONMENTAL RATINGS
|
Temperature Range |
Operating..................... –55°C to +70°C |
Non Operating............. –65°C to +125°C
|
Humidity............................. |
MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%) |
Shock................................. |
MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration........................... |
MIL-STD-202F, Method 204D, Cond. B (.06” double amplitude or 15G, whichever is less) |
Altitude............................. |
MIL-STD-202F, Method 105C, Cond. B (50,000 ft.) |