Series 91 and 92 Miniature Broadband SP5T Switches

                                               
 
  Contact Us         Application Notes for RF Switch
.

 

MODELS 9150-500 AND 9250-500

These switches provide high-performance characteristics over a multi-octave frequency range. The Model 9150-500 covers the 1 to 18 GHz frequency range while the Model 9250-500 covers the 0.2 to 4 GHz range. This description and operation are the same as that for the Models 9120-500 and 9220-500 SP2T switches.

MODELS 9150T-500, 9150W-500, AND 9250T-500

These switches are non-reflective versions of the switches described above.

SERIES F91 AND F92

The Series F91 and F92 switches are the same as the corresponding Series 91 and 92 models, except the units are equipped with integrated drivers.

SERIES G91 AND G92

These switches are the same as the Series G91 and G92 SP2T switches except for the number of ports.


  • Frequency range (Series 91): 1 to 18 GHz
  • Frequency range (Series 92): 0.2 to 4 GHz
  • Reflective and Non-reflective models
  • Low VSWR and Insertion loss
  • Isolation: up to 60 dB
  • Miniature size, light weight

Miniature Broadband SP5T Switch with Integrated Driver

F9150
(With INTEGRATED Driver)

Miniature Broadband SP5T Switch Driverless Model

9150-500
(DRIVERLESS)



MODEL NO.(1) CHARACTERISTIC FREQUENCY (GHz)
0.2-1 1-2 2-4 4-8 8-12.4 12.4-18
9150-500*
F9150*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)


60
1.5
1.5
60
1.5
1.5
55
1.5
1.75
50
2.0
1.75
50
3.0
2.0
G9150* Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (
ON)


60
2.2
1.5
60
2.2
1.5
60
2.4
1.8
60
3.0
2.0
50
3.3
2.2
9250-500*
F9250*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
60
1.5
1.6
60
1.5
1.6
60
1.5
1.6






G9250* Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
60
2.2
1.5
60
2.2
1.5
60
2.2
1.5






9150T-500*
F9150T*
G9150T*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON or OFF)


50
1.5
1.5
50
1.5
1.5
45
2.0
1.7
40
2.5
2.0
40
3.0
2.2
9250T-500*
F9250T*
G9250T*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON or OFF)
60
1.4
1.5
60
1.4
1.5
50
1.5
1.5






9150W-500*
F9150W
G9150W*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON or OFF)


60
2.2
1.5
60
2.2
1.7
60
2.4
1.8
60
3.0
2.0
55
3.3
2.2

*Special-order product. Consult factory before ordering.

 (1) Models prefixed with "F" or "G" are equipped with integrated TTL-compatible drivers; models without the "F" or "G" prefix are current-controlled units and are furnished without drivers; models suffixed with "T" or "W" are non-reflective except a high VSWR will be present at the common port if all other ports are OFF.


PERFORMANCE CHARACTERISTICS

Power Handling Capability
Without Performance Degradation
      Units without "T" or "W" suffix:1W cw or peak
      Units with "T" or "W" suffix
            Input to any "OFF" port: 100 mW cw or peak
            Input to any "ON" port: 1W cw or peak
            Input to common port: 1W cw or peak
Survival Power
      Units without "T" or "W" suffix: 1W average,
            75W peak (1μsec max. pulse width)
      Units with "T" or "W" suffix:
            Input to any "OFF" port: 1W average,
                  10W peak (1μsec max. pulse width)
            Input to any "ON" port: 1W average,
                  75W peak (1μsec max. pulse width)
            Input to common port:1W average,
                  75W peak (1μsec max. pulse width)
 
Switching Time(2)
SERIES 91/F91/G91
      ON time.............................. 250 nsec max.
      OFF time............................. 250 nsec max.
      With Option C37 100 nsec max.
SERIES 92/F92/G92
      ON time................................ 500 nsec max.
      OFF time.............................. 500 nsec max.
 (2) For driverless units, shaped current pulses must be provided by the user  
   
Power Supply Requirements
SERIES 91/92/F91/F92
Driverless Units
Bias current required at each port for rated isolation and Insertion loss.
      Port OFF............................... +50 mA
      Port ON................................. -50 mA
Units With Integrated Drivers
(For one port ON) ....................

+5V ±5%, 250 mA
-12 to -15V, 80 mA
SERIES G91/G92
(For one port ON) .....................
 
+5V ±5%, 150 mA
+15V ±5%, 60 mA
Control Characteristics
SERIES 91/92/F91/F92
Units With Integrated Drivers
Control Input
      Impedance
.............................
 
 

TTL, low power Schottky, one unit load. (A unit load is 0.8 mA sink current and 40 μA source current.)
Control Logic..............................


Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF.
SERIES G91/G92
 
Control Input
 
Impedance................................



Schottky TTL, one unit load. (A unit load is 2.0 mA sink current and 50 μA source current.)
Control Logic..............................
 
 

Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF.


 
ENVIRONMENTAL RATINGS - Option G09
Temperature Range
   
      Operating................................. -54°C to +110°C
      Non-Operating........................ -65°C to +125°C
   
      
Humidity.......................................... MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%)
Shock.............................................. MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec)
Vibration......................................... MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less)
Altitude............................................ MIL-STD-202F, Method 105C, Cond. B (50,000 ft.)
Temp. Cycling................................ MIL-STD-202F, Method 107D, Cond. A, 5 cycles
 
Available Options
Option No.       Description
3 SMA female bias/control connectors
.
7 SMA male RF connectors
.
9




Inverse control logic; logic "0" for port OFF and logic "1" for port ON (Not applicable to Series 91/92)
33

EMI filter solder-type bias/control terminals
41*

Internal video filter, common port only
42*

Internal video filter, output ports only
43*

Internal video filter, all ports

55

Frequency range 0.5 to 18 GHz. See impact of this Option on the specifications.
64A

SMB male bias/control connectors
C37** 100 nsec. switching time
G09 Guaranteed to meet Environmental Ratings
G12 RoHS Complant
G16 RoHS Plus REACH Compliant



 *Not applicable to Series 92/F92/G92. See Video Filter Options on Switches

**Not applicable to series 92/F92/C92. Minimum order buy of 100 switches


DIMENSIONS AND WEIGHTS

Dimensions and Weights for Series 91 and 92 SP5T Switches

Dimensional Tolerances, unless otherwise indicated: .XX ±.02; .XXX ±.005