Switching Time |
ON time.................................................. |
500 nsec max. |
OFF time................................................ |
500 nsec max. |
Power Handling Capability |
Without Performance Degradation ...... |
To OFF port 100 mW cw or peak.
To ON port 500 mW |
Survival Power...................................... |
To OFF port 1W average, 10W peak, and 75W peak to ON port (1 µsec max. pulse width) |
Power Supply Requirements...................
|
+5V ±5%, 190 mA
-12V ±5%, 60 mA |
|
Control Characteristics |
Control Input Impedance ...................... |
Schottky TTL, two unit loads. (A unit load is 2 mA sink current and 50 µA source current.) |
Control Logic.........................................
|
Logic "0" (-0.3 to +0.8V) for port ON. Logic "1" (+2.0 to +5.0V) for port OFF.
|
|
OPTION (G09) ENVIRONMENTAL RATINGS |
Operating Temperature Range .......... |
-55°C to +110°C |
Non-Operating Temperature Range ..
|
-65°C to +125°C |
Humidity ............................................. |
MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%) |
Shock ................................................. |
MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration ............................................ |
MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less) |
Altitude .............................................. |
MIL-STD-202F, Method 105C, Cond. B (50,000 ft) |
Temp. Cycling .................................... |
MIL-STD-202F, Method 107D, Cond. A, 5 cycles |
|
|
|
|
ACCESSORY FURNISHED |
|
Mating power/logic connector |
|
|
|
|
|
AVAILABLE OPTIONS |
|
Option No. Description
|
G09 Guaranteed to meet Environmental Ratings
|
G12 RoHS Compliant
|
G18 REACH Compliant |
|
|
|