NOTE
(2) For driverless units, shaped current pulses must be provided by user.
|
Power Supply Requirements |
SERIES 91/92/F91/F92 |
Driverless Units |
Bias current required at each port for rated isolation and Insertion loss. |
Port OFF........................................... |
+50 mA |
Port ON............................................. |
-50 mA |
Units With Integrated Drivers |
(For one port ON)................................
|
+5V ±5%, 375 mA
-12V to -15V, 60 mA |
SERIES G91/G92 |
(For one port ON)................................
|
+5V ±5%, 190 mA
+15V ±5%, 70 mA |
Control Characteristics |
SERIES 91/92/F91/F92
Units With Integrated Drivers |
Control Input Impedance.................
|
TTL, low power Schottky, one unit load. (A unit load is 0.8 mA sink current and 40 μA source current.) |
Control Logic....................................
|
Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF. |
SERIES G91/G92 |
Control Input Impedance.................
|
Schottky TTL, one unit load. (A unit load is 2.0 mA sink current and 50 μA source current.) |
Control Logic....................................
|
Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF.
|
|
|
OPTION (G09) ENVIRONMENTAL RATINGS |
Temperature Range
|
|
Operating............................................. |
-54°C to +110°C |
Non-Operating..................................... |
-65°C to +125°C |
Humidity...................................................
|
MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%) |
Shock........................................................
|
MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration................................................... |
MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less) |
Altitude..................................................... |
MIL-STD-202F, Method 105C, Cond. B (50,000 ft.) |
Temp. Cycling...........................................
|
MIL-STD-202F, Method 107D, Cond. A, 5 cycles
|
|
|
AVAILABLE OPTIONS
|
|
Option No. Description |
3 SMA female bias/control connectors |
7 SMA male RF connectors
|
9 Inverse control logic; logic "0" for port OFF and logic "1" for port ON (Not applicable to Series 91, 92) |
33 EMI filter solder-type bias/control terminals |
41(3) Internal video filter, common port only
|
42(3) Internal video filter, output ports only
|
43(3) Internal video filter, all port |
55 Frequency range 0.5 to 18 GHz. See impact of this Option on specifications. |
64A SMB male bias/control connectors |
C37(4) 100 nsec switching time
|
G09 Guaranteed to meet Environmental Ratings |
G12 RoHS Compliant |
G18 REACH Compliant |
|
|
NOTES |
|
(3) Not applicable to Series 92/F92/G92. See Video Filter Options on Switches |
(4) Not applicable to series 92/F92/G92. Minimum order buy of 100 switches |
|
|
DIMENSIONS AND WEIGHT
MODELS 91/92/F91/F92/G91/G92
Wt: 2.9 oz. (82 gm) approx.
|
|