Power Handling Capability |
Without Performance Degradation |
Units without "T" or "W" suffix: 1W cw or peak |
Units with "T" or "W" suffix: |
Input to any "OFF" port:100 mW cw or peak |
Input to any "ON" port:1W cw or peak |
Input to common port:1W cw or peak |
Survival Power |
Units without "T" or "W" suffix: 1W average, 75W peak (1μsec max. pulse width) |
Units with "T" or "W" suffix: |
Input to any "OFF" port:1W average, 10W peak (1μsec max. pulse width) |
Input to any "ON" port:1W average, 75W peak (1μsec max. pulse width) |
Input to common port:1W average, 75W peak (1μsec max. pulse width |
|
Switching Time(2) |
SERIES 91/F91/G91 |
ON time......................................... |
250 nsec max. |
OFF time........................................ |
250 nsec max. |
With Option C37............................... |
100 nsec max. |
SERIES 92/F92/G92 |
ON time.......................................... |
500 nsec max. |
OFF time........................................ |
500 nsec max. |
NOTE
(2) For driverless units, shaped current pulses must be provided by the user.
|
Power Supply Requirements |
SERIES 91/92/F91/F92 |
Driverless Units |
Bias current required at each port for rated isolation and Insertion loss. |
Port OFF...................................... |
+50 mA |
Port ON........................................ |
-50 mA |
Units With Integrated Drivers |
(For one port ON)............................
|
+5V ±5%, 315 mA
-12 to -15V, 100 mA |
SERIES G91/G92 |
(For one port ON)...............................
|
+5V ±5%, 150 mA
+15V ±5%, 70 mA |
Control Characteristics |
SERIES 91/92/F91/F92 |
Units With Integrated Drivers |
Control Logic.................................
|
Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF. |
Control Input Impedance.............
|
TTL, low power Schottky, one unit load.(A unit load is 0.8 mA sink current and 40 μA source current.) |
SERIES G91/G92 |
Control Logic.................................
|
Logic "0" (-0.3 to +0.8V) for port ON and logic "1" (+2.0 to +5.0V) for port OFF. |
Control Input Impedance..............
|
Schottky TTL, one unit load. (A unit load is 2.0 mA sink current and 50 μA source current.) |
|
|
OPTION (G09) ENVIRONMENTAL RATINGS |
Temperature Range
|
|
Operating......................................... |
-54°C to +110°C |
Non-Operating................................ |
-65°C to +125°C |
Humidity..............................................
|
MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%) |
Shock...................................................
|
MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) |
Vibration.............................................. |
MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less)
|
Altitude................................................ |
MIL-STD-202F, Method 105C, Cond. B (50,000 ft.) |
Temp. Cycling...................................... |
MIL-STD-202F, Method 107D, Cond. A, 5 cycles |
|
|
AVAILABLE OPTIONS
|
|
Option No. Description
|
3 SMA female bias/control connectors |
7 SMA male RF connectors |
9 Inverse control logic; logic "0" for port OFF and logic "1" for port ON (Not applicable to Series 91/92)
|
33 EMI filter solder-type bias/control terminal
|
41(3) Internal video filter, common port only |
42(3) Internal video filter, output ports only
|
43(3) Internal video filter, all ports
|
64A SMB male bias/control connectors
|
C37(4) 100 nsec. switching time
|
G09 Guaranteed to meet Environmental Ratings
|
G12 RoHS Compliant |
G18 REACH Compliant |
|
NOTES |
(3) Not applicable to Series 92/F92/G92. See Video Filter Options on Switches |
(4) Not applicable to series 92/F92/C92. Minimum order buy of 100 switches
|