Series 91 and 92 Miniature Broadband SP4T Switches

 

  Contact Us         Application Notes for RF Switches

 


MODELS 9140-500 AND 9240-500

These switches provide high-performance
characteristics over a multi-octave frequency range. Model 9140-500 covers the 1 to 18 GHz frequency range while the Model 9240-500 covers the 0.2 to 4 GHz range. Their description and operation are the same as that for the Models 9120-500 and 9220-500
SP2T switches.

MODELS 9140T-500, 9140W-500
AND 9240T-500
These switches are Non-reflective versions of the switches described above.

MODELS 9140AH-500 AND 9140AHT-500
These switches are the same as the 9120AH-500 and the 9120AHT-500 except for the number of ports.

SERIES F91 AND F92
The Series F91 and F92 switches are the same as the corresponding Series 91 and 92 models except the units are equipped with integrated drivers.

SERIES G91 AND G92
These switches are the same as the Series G91 and G92 SP2T switches except for the number of ports.

  • Frequency range (Series 91): 1 to 18 GHz
  • Frequency range (Series 92): 0.2 to 4 GHz
  • Rise and fall times as fast as 10 nsec
  • Reflective and Non-reflective models
  • Low VSWR and Insertion loss
  • Isolation: up to 60 dB
  • Miniature size, light weight

Miniature Broadband SP4T Switch with Integrated Driver
F9140AH-33
(With INTEGRATED Driver)



Miniature Broadband SP4T Switch Driverless Model
9140AH-500
(DRIVERLESS)

MODEL
NO.(1)
CHARACTERISTIC FREQUENCY (GHz)
0.2-1 1-2 2-4 4-8 8-12.4 12.4-18
9140-500
F9140
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
-
-
-
60
1.4
1.75
60
1.4
1.75
60
1.5
1.75
60
2.0
1.75
50
2.8
2.0
G9140*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
-
-
-
60
2.0
1.5
60
2.0
1.5
60
2.2
1.7
60
2.7
1.7
50
3.0
2.0

9240-500*
F9240*

Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
60
1.5
1.6
60
1.5
1.6
60
1.5
1.6
-
-
-
-
-
-
-
-
-
G9240* Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
60
2.0
1.5
60
2.0
1.5
60
2.0
1.5
-
-
-
-
-
-
-
-
-
9140T-500*
F9140T*
G9140T*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON or OFF)
-
-
-
50
1.5
1.5
50
1.5
1.5
45
1.7
1.7
40
2.0
1.7
40
2.5
2.0
9240T-500*
F9240T*
G9240T*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON or OFF)
50
1.3
1.5
50 
1.3
1.5
50 
1.5
1.5
-
-
-
-
-
-
-
-
-
9140W-500*
F9140W
G9140W*
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON or OFF)
-
-
-
60
2.0
1.5
60
2.0
1.7
60
2.2
1.7
60
2.7
2.0
55
3.0
2.0
9140AH-500*
F9140AH
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
-
-
-
60
1.4
1.75
60
1.4
1.75
60
1.5
1.75
60
2.0
2.0
50
2.8
2.0
9140AHT-500*
F9140AHT
Min. Isolation (dB)
Max. Insertion Loss (dB)
Max. VSWR (ON)
Max. VSWR (OFF)
-
-
-
-
60
1.6
1.75
1.75
60
1.6
1.75
1.75
60
1.8
1.9
2.0
60
2.5
2.0
2.2
50
3.3
2.0
2.3


*Special-order product. Consult factory before ordering.

 PRFORMANCE CHARACTERISTICS
Power Handling Capaility
Without Performance Degradation
Units without "T" or "W" suffix: 1W cw or peak
Units with "T" or W suffix
   Input to any "OFF" port: 100 mW cw or peak
   Input to any "ON" port: 1W cw or peak
   Input to common port: 1W cw or peak                         

 Survival Power

Units without "T" or "W" suffix: 1W average   75W peak (1 µsec max. pulse width)Units with “T” or “W” suffix   Input to any “OFF” port: 1W average,      10W peak (1 µsec max. pulse width)   Input to any “ON” port: 1W average,      75W peak (1 µsec max. pulse width)   Input to common port: 1W average,      75W peak (1 µsec max. pulse width)

(1) Models prefixed with “F” or “G” are equipped with integrated TTL-compatible drivers; models without the “F” or “G” prefix are currentcontrolled units and are furnished without drivers; models suffixed with “T” or “W” are non-reflective except a high VSWR will be present at the common port if all other ports are OFF; models suffixed with “H” are high-speed units.

 

Switching Characteristics(1) Control Characteristics
SERIES 91/F91/G91 SERIES 91/92/F91/F92
Units without “H” suffix Units With Integrated Drivers
   ON time ........................................... 250 nsec max. Non-Operating Temperature
   OFF time ......................................... 250 nsec max. Control Input Impedance
Units with “H” suffix    Units without “H” suffix................. TTL, low power Schottky,one unit load. (A unit load is 0.8 mA sink current and 40 µA source current.)


   Rise time ........................................ 10 nsec max.  
   Fall time........................................... 10 nsec max.  
   ON time ........................................... 25 nsec max.  
   OFF time .......................................... 20 nsec max.    Units with “H” suffix ..................... TTL, advanced Schottky, one unit load. (A unit load is 0.6 mA sink current and 20 µA source current.)


   Repetition rate ................................. 20 MHz max.  
SERIES 92/F92/G92  
   ON time ............................................. 500 nsec max.  
   OFF time ............................................ 500 nsec max. Control Logic .................................. Logic “0” (–0.3 to +0.8V) for port ON and logic “1”(+2.0 to +5.0 V) for portOFF.


     
Power Supply Requirements  
SERIES 91/92/F91/F92  
Driverless Units  
Bias current required at each port for rated isolation SERIES G91/G92  
and Insertion loss. Control Input Impedance ........... Schottky TTL, one unit load. (A unit load is 2.0 mA sink current and 50 µA source current.)


   PORT OFF    
      Units without “H” suffix .................. +50 mA  
      Units with “H” suffix ....................... +30 mA
   PORT ON   Control Logic ................................. Logic “0” (–0.3 to +0.8V) for port ON and logic “1” (+2.0 to +5.0 V) for port OFF.


      Units without “H” suffix .................. –50 mA  
      Units with “H” suffix ....................... –35 mA
Units With Integrated Drivers
(For one port ON)    
  +5V ± 5% –12 to –15V
Units Without
H” Suffix
190 mA 80 mA
Units With
“H” Suffix
95 mA 80 mA
Units With
“HT” Suffix
135 mA 80 mA

 

 

 

 



SERIES G91/G92
(For one port ON)

  +5V ±5%, 100 mA
   +15V ±5%, 40 mA


(1) For driverless units, shaped current pulses must be provided by user.

OPTION (G09) ENVIRONMENTAL RATINGS AVAILABLE OPTIONS
 Temperature Range  
         Operating  Range ............ –54°C to +110°C 3 SMA female bias/control connectors
        Non-Operating  Range .... –65°C to +125°C 7 SMA male RF connectors
Humidity ....................................  MIL-STD-202F, Method 103B, Cond. B (96 hrs. at 95%)  33 EMI filter solder-type bias/control
    terminals
Shock ......................................... MIL-STD-202F, Method 213B, Cond. B (75G, 6 msec) 41(1) Internal video filter, common port only
  42(1) Internal video filter, output ports only
Vibration .................................... MIL-STD-202F, Method 204D, Cond. B (.06" double amplitude or 15G, whichever is less)

43(1) Internal video filter, all ports
  55(2) Frequency range 0.5 to 18 GHz.
  64A SMB male bias/control connector
G09 Guaranteed to meet Environmental Ratings
G12 RoHS Compliant
G16 RoHS Plus REACH Compliant
.
NOTES
(1) Not applicable to Series 92//F92/G92. See impact of Video Filter Options on specifications at Switches Applications Notes.
(2) Applicable only to 1 to 18 GHz switches. See impact of Option  55 on specifications
Altitude ....................................... MIL-STD-202F, Method 105C, Cond. B (50,000 ft.)
   
Temp. Cycling .......................... MIL-STD-202F, Method 107D Cond. A, 5 cycles    
       

(1) Not applicable to Series 92//F92/G92. See impact of Video Filter Options on specifications at Switches Applications Notes.

(2) Applicable only to 1 to 18 GHz switches. See impact of Option  55 on specifications


DIMENSIONS AND WEIGHT

Dimensions and Weights for Series 91 and 92 SP4T Switches

Weight 2 oz. (57 grams) approx. 

 Dimensional Tolerances, unless otherwise indicated: .XX ±.02; .XXX ±.005